2017-11-28 21:39 I 阅读:88
Approximately 2700 – 6000 tons of mercury are released into the at mosphere annually. Once airborne, mercury can travel thousand mile s from its generation point. Eventually, it precipitates onto the l and and water. And once it enters water, mercury is transformed by microorganisms into methylmercury, the most toxic and dangerous for m of mercury. Exposure to high dosage of methylmercury can cause tremors, inabili ty to walk, convulsions and even death. Children exposed to the mercury show a variety of abnormalities such as delayed onset of walking and talking, cerebra l palsy, and slowed neurological reflexes and learning abilities. One of the best indicators of exposure to mercury is testing for co ncentration in hair and blood. The average concentration of mercur y in non-exposed people is about 8 ppb in blood and 2 ppm in hair Mercury has traditionally been measured in hair, blood, tissues, an d urine by CVAAS (Cold Vapor Atomic Absorption Spectrophotometry), which is a time and labor consuming method that relies on complicat ed wet chemistry sample preparation. The DMA-80 Direct Mercury Analyzer from Milestone eliminates the sa mple preparation step, allowing you to rapidly process your samples in m inutes, instead of the hours needed for traditional methods. This r apid testing (which is as accurate, if not more so, that CVAAS) giv es you the answers you need without consuming valuable time and eff ort. Other benefits include: Process both liquid and solid samples – no matter how difficult th e matrix you will get an accurate total mercury reading. The built-in 40-position autosampler allows unattended operation fo r a large number of samples The DMA-80 is portable enough to be stationed where you need it mos t; in your laboratory, in a portable testing van, etc... No chemicals are used in the process so no additional toxic wastes are generated. Completely compatible with US EPA Method 7473
下载资料
使用DMA-80直接测汞仪测定临床样品(血液、尿和头发)中的汞含量(英文版).pdf
相关资料
2023-01-10
科学仪器让生活更多彩——如何自制口红
2188KB
-
摘要
科学仪器让生活更多彩——利用光波加热仪和微控数显电热板自制口红
阅读详情
2023-01-06
环境空气中苯并 [α] 芘的测定
1824KB
+
摘要
本方案参考《HJ 956-2018 环境空气 苯并 [α] 芘的测定 高效液相色谱法》,使用 Flex-HPSE 全自动高效快速溶剂萃取系统提取、SPE1000 全自动固相萃取系统净化、M64 高通量平行浓缩仪浓缩、二元高压梯度液相色谱系统检测,建立了一种环境空气中苯并 [α] 芘含量检测的分析方法。
阅读详情
2023-01-06
固定污染源废气中挥发性有机物的测定
1772KB
+
摘要
本方法参考《HJ 734-2014 固定污染源废气 挥发性有机物的测定 固相吸附 - 热脱附 / 气相色谱 - 质谱法》的测试方法,使用 CDS7550S 全自动热解析仪建立了固定污染源废气中挥发性有机物的检测方法。方法得到的挥发性有机物校准曲线 r 均在 0.996 以上,回收率为 93.6%~108.4%,RSD 为 1.2%~9.8%。都满足了HJ734-2014 中相应的要求。
阅读详情
2023-01-06
土壤中的 64 种 SVOCs 的测定
1878KB
+
摘要
本方案参考《HJ 834-2017 土壤和沉积物 半挥发性有机污染物的测定 气相色谱 - 质谱法》,使用莱伯泰科高效快速溶剂萃取系统(HPSE)提取土壤中的 64 种 SVOCs,GPC1000 全自动凝胶净化系统净化,MultiVap-10 多通道平行浓缩仪浓缩后用气质联用仪进行检测,建立了一种土壤中 64 种半挥发性有机污染物的分析方法。
阅读详情
联系我们:
客服电话:400-099-8176
企业名称:北京莱伯泰科仪器股份有限公司
企业地址:顺义区空港工业区 B 区安庆大街 6 号 联系人:市场部 邮编:101312
Copyright©2026 北京莱伯泰科仪器股份有限公司 京ICP备17072199号-3 技术支持:仪器信息网